Operation CHARM: Car repair manuals for everyone.

Exhaust Turbocharger Outlet Pipe Adapter Installation




Exhaust Turbocharger Outlet Pipe Adapter Installation





Caution:
Refer to Fastener Caution Fastener Caution

1. Install the exhaust adapter (2) and exhaust adapter clamp (1) and tighten to 10 Nm (89 lb in).





2. Install the indirect fuel injector (4).

3. Install the indirect fuel injector retainer (3) into the fitting.

4. Install the indirect fuel injector bolts (1) and tighten to 25 Nm (18 lb ft).

5. Install the fuel feed pipe clip bolts (2) and tighten to 25 Nm (18 lb ft).

6. Tighten the indirect fuel injector to exhaust outlet adapter fitting to 45 Nm (33 lb ft).





Caution:
Care should be taken while handling the exhaust temperature sensor to prevent internal damage.

7. Install the exhaust temperature sensor (1) and tighten to 19 Nm (14 lb ft).





8. Install the NOx sensor (1) and tighten to 45 Nm (33 lb ft).





9. Install the exhaust adapter to right exhaust pipe bracket bolt (1) and tighten to 34 Nm (25 lb ft).





10. Install the exhaust adapter heat shield (2).

11. Install the exhaust adapter heat shield bolts (1) and tighten to 10 Nm (89 lb in).