Operation CHARM: Car repair manuals for everyone.

Power Outlet Receptacle Inoperative (120 VAC)




Power Outlet Receptacle Malfunction

Diagnostic Instructions

* Perform the Diagnostic System Check - Vehicle Diagnostic System Check - Vehicle prior to using this diagnostic procedure.

* Review Strategy Based Diagnosis Strategy Based Diagnosis for an overview of the diagnostic approach.

* Diagnostic Procedure Instructions Diagnostic Procedure Instructions provides an overview of each diagnostic category.

Diagnostic Fault Information






Circuit/System Description

The vehicle is fitted with a 12 V accessory power receptacle. The accessory power outlets are controlled by an ignition operated relay. The accessory power receptacle is operational when the ignition is turned to either the On or the Accessories positions.

Diagnostic Aids

It may be helpful to discuss with the customer the usage of any device that may have drawn too much current and caused an open fuse.

Reference Information

Schematic Reference

Cigar Lighter/Power Outlet Schematics [1][2]Auxiliary Power Outlet

Connector End View Reference

Component Connector End Views Sunshade - Left Front

Description and Operation

Power Outlets Description and Operation Description and Operation

Electrical Information Reference

* Circuit Testing Circuit Testing

* Connector Repairs Connector Repairs

* Testing for Intermittent Conditions and Poor Connections Testing for Intermittent Conditions and Poor Connections

* Wiring Repairs Wiring Repairs

Circuit/System Verification

1. Ignition ON, connect an appropriate device to the X80 Accessory Power Receptacle.

2. Verify the device is powered by the X80 Accessory Power Receptacle.

If the device is not powered
Refer to Circuit/System Testing

If the device is powered

3. All OK.

Circuit/System Testing

1. Ignition OFF, disconnect the harness connector at the appropriate X80 Accessory Power Receptacle.

2. Test for less than 10 ohms between the ground circuit terminal C and ground.

If greater than 10 ohms

1. Ignition OFF.

2. Test for less than 2 ohms in the ground circuit end to end.

If 2 ohms or greater, repair the open/high resistance in the circuit.

If less than 2 ohms, repair the open/high resistance in the ground connection.

If less than 10 ohms

3. Ignition ON.

4. Verify that a test lamp illuminates between the control circuit terminal A and ground.

If the test lamp does not illuminate and the circuit fuse is good

1. Ignition OFF.

2. Test for less than 2 ohms in the control circuit end to end.

If greater than 2 ohms, repair the open/high resistance in the circuit.

If less than 2 ohms, verify the fuse is not open and there is voltage at the fuse. Refer to Retained Accessory Power Malfunction Retained Accessory Power Malfunction.

If the test lamp does not illuminate and the circuit fuse is open

1. Ignition OFF.

2. Test for infinite resistance between the control circuit terminal A and ground.

If less than infinite resistance, repair the short to ground on the circuit.

If infinite resistance, replace the appropriate X80 Accessory Power Receptacle.

If the test lamp illuminates

5. Replace the appropriate X80 Accessory Power Receptacle.

Repair Instructions

Perform the Diagnostic Repair Verification Verification Tests after completing the repair.

Accessory Power Receptacle Replacement Service and Repair.