Leak Test
Tools Required:J 23575-B Manifold Gage Set
J 26934 H-10B Electronic Leak Detector
Following overhaul of the compressor, conduct this leak test to make sure that unit reassembly was sound.
1. Connect a J 23575-B to compressor service valve.
2. Charge compressor with refrigerant from a refrigerant drum until the pressure is 296 kPa (43 psi).
3. Check component for leaks using a J 26934.
4. If leakage is found, repair or replace compressor.