Compressor Leak Test
Tools Required:J23575-B Manifold Gage Set
J 39400 Leak Detector
Following overhaul of the compressor, conduct this leak test to make sure that unit reassembly is sound.
1. Connect a J 23575-B to compressor service valve.
2. Charge compressor with refrigerant from a refrigerant drum until pressure is 296 kPa (43 psi).
3. Check component for leaks using a J 39400.
4. If leakage is found, repair or replace the compressor.