Air Temperature Sensor ( Ambient / Intake ): Service and Repair
REMOVE OR DISCONNECT
1. Negative (-) battery cable.
2. Intake Air Temperature (IAT) sensor electrical connector.
3. IAT sensor from Air Cleaner (ACL).
INSTALL OR CONNECT
1. IAT sensor to air cleaner. Tighten IAT sensor to 13-17 Nm (9.5-12.0 lb. ft.).
2. IAT sensor electrical connector.
3. Negative (-) battery cable. Tighten Negative (-) battery cable-to-negative (-) battery terminal retainer to 15 Nm (11 lb. ft.).