Operation CHARM: Car repair manuals for everyone.

Shift Solenoid Valve B Test

Shift Solenoid Valve B Test





1. Disconnect the connector from shift solenoid valve B.
2. Remove shift solenoid valve B.
3. Measure shift solenoid valve B resistance at the solenoid valve connector (brown).
STANDARD: 12 - 25 Ohms
4. Replace the shift solenoid valve B if the resistance is out of standard.
5. If the resistance is within the standard, connect the No. 2 terminal of the shift solenoid valve B connector to the battery positive terminal, and connect the No. 1 terminal to the battery negative terminal. A clicking sound should be heard. Replace the shift solenoid valve B if no clicking sound is heard.