Standards and Service Limits

Alternator belt Tension adjustment Auto adjuster type
Starter Commutator mica depth Standard or new 0.04 - 0.5 mm
Service limit 0.15 mm
Commutator runout Standard or new 0.02 mm maximum
Service limit 0.05 mm
Commutator O.D. Standard or new 28.0 - 28.1 mm
Service limit 27.5 mm
Brush length Standard or new 15.8 - 16.2 mm
Service limit 11.0 mm
Brush spring tension (new) 15.7 - 17.7 N