Standards and Service Limits
Starter for M/T (DENSO) | Output | 1.0 kW | |
Commutator mica depth | Standard or new | 0.45 - 0.75 mm | |
Service limit | 0.2 mm | ||
Commutator runout | Standard or new | 0.02 mm maximum | |
Service limit | 0.05 mm | ||
Commutator O.D. | Standard or new | 27.9 - 28.0 mm | |
Service limit | 27.0 mm | ||
Brush length | Standard or new | 14.0 - 14.5 mm | |
Service limit | 9.0 mm | ||
Brush spring tension | 14 - 20 N | ||
Starter for A/T (MITSUBA) | Output | 1.2 kW | |
Commutator mica depth | Standard or new | 0.4 - 0.6 mm | |
Service limit | 0.2 mm | ||
Commutator runout | Standard or new | 0.02 mm maximum | |
Service limit | 0.05 mm | ||
Commutator O.D. | Standard or new | 28.0 - 28.1 mm | |
Service limit | 27.5 mm | ||
Brush length | Standard or new | 15.8 - 16.2 mm | |
Service limit | 11.0 mm | ||
Brush spring tension | 16 - 18 N |