Operation CHARM: Car repair manuals for everyone.

Gauge Assembly

NOTE: The IMA battery level gauge will go off in the following cases :

- When the battery is removed
- When the gauge assembly is removed
- When the No.16 (30 A) or No.18 (7.5 A) fuse in the under-hood fuse/relay box is removed

After about 30 minutes driving, the IMA battery level gauge will come on.

1. Remove the instrument panel.




2. Remove the screws from the gauge assembly (A), and spread a protective cloth (B) on the upper column cover.
3. Disconnect the connectors (C), and remove the gauge assembly.
4. Install in the reverse order of removal.