Trunk / Liftgate Switch: Testing and Inspection
Trunk Opener Switch Test1. Remove the rear console).
2. Disconnect the 2P connector from the switch.
3. Check for continuity between the No.1 and No.2 terminals.
- There should be continuity when the switch is pushed.
- There should be no continuity when the switch is released.
4. If the continuity check is not as specified, replace the switch.