Ignition Relay: Testing and Inspection
IG2 RelayFive-terminal type B:
Check for continuity between the terminals.
- There should be continuity between the No. and No.2 terminals when power and ground are connected to the No.3 and No.5 terminals.
- There should be continuity between the No. 1 and No.4 terminals when power is disconnected.
- Rear window defogger relay