Air Injection Pump Relay: Testing and Inspection
Air Pump Relay TestCheck for continuity between the terminals according to the table.
- There should be continuity between the A1 and A2 terminals of the air pump relay 2P large connector when power and ground are connected to the B1 terminal of the air pump relay 2P small connector.