Seat Temperature Element: Testing and Inspection
SEAT WARMERINSPECTION
1. Check for continuity and measure the resistance between No. 1 and N03 terminals.
Standard value Cushion : 4.73 ohms ± 10%, Back : 4.97 ohms ± 10%
2. Operate the seat warmer after connecting the 3P connector, and then check the thermostat by measuring the temperature of seat surface.
3. Check for continuity between the terminals after disconnecting the connector.
Standard value HI : 42 ± 2° C (Cushion), 52 ± 2° C (Back)