Hazard Flasher Relay: Testing and Inspection
HAZARD LAMP RELAYINSPECTION
1. Disconnect the negative (-) battery terminal.
2. Disconnect the passenger compartment.
3. Check for continuity between terminals. There should be continuity between the No. 2 of I/P-C and No. 3 or No. 4 of I/P-E terminals when power and ground are connected to the No. 2 of I/P-C and No. 6 of I/P-G terminals.
4. There should be no continuity between the No. 2 of I/P-C and No. 3 or No. 4 of I/P-E terminals when power is disconnected to the No. 2 of I/P-C and No. 6 of I/P-G terminals.