Monitor Scantool Data
Monitor Scantool Data
1. Connect scantool to Data Link Connector (DLC).
2. Engine "ON".
3. Monitor the "Intake potentiometer" Parameter on the Scantool. While operating Intake switch.
Fig 1) The current data in abnormal state
Fig 2) DTC B2408
4. Are the DTC B2408 present and is parameter of "Intake potentiometer" fixed ?
NOTE: