Component Inspection
Component Inspection
1. Check OCV
(1) IG "OFF" and disconnect OCV connector.
(2) Measure resistance between terminal 1 and 2 of OCV. (Component Side)
Specification : 6.7 - 7.7 ohms at 20 °C (68 °F)
(3) Is the measured resistance within specification ?
2. OCV Actuation Test
(1) Connect scantool and IG "ON"
(2) Select "OCV" on the Actuation Test
(3) Activate "OCV" by pressing "STRT (F1)" key
(should hear a faint click from Oil Control solenoid Valve)
(4) Repeat this procedure 4 or 5 times to ensure reliability
(5) Does OCV generate click sound during actuation test ?