Operation CHARM: Car repair manuals for everyone.

Shift Solenoid: Testing and Inspection

1. Remove the solenoid connector.




2. Using an ohmmeter, measure the resistance between terminals.
Standard resistance ................................. 12-16 Ohms




3. Attach the positive (+) lead from the battery to terminal 1, and the negative (-) lead to terminal 2.
4. Check that an operation noise can be heard from the solenoid.