Operation CHARM: Car repair manuals for everyone.

Shift Interlock Solenoid: Testing and Inspection

1. Remove the solenoid connector.




2. Using an ohmmeter, measure the resistance between terminals.
Resistance between terminals ........................... 12.5-16.5 Ohms




3. Attach the positive (+) lead from the battery to terminal 2 and the negative (-) lead to terminal 1.
4. Check that an operating noise can be heard from the solenoid.