Automatic Stop Operation Check
1. Operate the motor at low speed.
2. Stop the motor operation anywhere except the off position by disconnecting terminal 1.
3. Connect terminals 5 and 1.
4. Connect the positive (+) lead from the battery to terminal 4 and ground terminal 3.