Ignition Coil: Testing and Inspection
INSPECT IGNITION COIL1. Measure the primary coil resistance between terminals 1,2 and 1,3.
Standard value : 0.58 K ohms +/- 10%
2. Measure the secondary coil resistance between the high-voltage terminal for the No.1 and No.4 cylinders, and between the high-voltage terminals for the No.2 and No.3 cylinders.
Standard value : 8.8 K ohms +/- 15%
CAUTION: Be sure, when measuring the resistance of the secondary coil, to disconnect the connector of the Ignition coil.