CIRCUIT DESCRIPTION

Battery voltage is applied at all times from the positive battery terminal to the ignition switch and the normally open start relay contacts. When the ignition switch is turned to START and the transaxle range switch (automatic transaxle) is in P/N position, battery voltage is applied through fuse 32 to the start relay coils. The start relay coils energize, the start relay contacts close, and battery voltage is applied to the start solenoid. The motor engages to start the engine.