Seat Temperature Element: Testing and Inspection
SEAT WARMERINSPECTION
1. Check for continuity and measure the resistance between No.1 and No.3 terminals.
Standard value Cushion : 3.04 ohms ± 10% Back : 3.04 ohms ± 10%
2. Operate the seat warmer after connecting the 3P connector, and then check by measuring the temperature of seat surface.
3. Check for continuity between No.1 and No.3 terminals after disconnecting the 3P connector.