Alarm Horn: Testing and Inspection
BURGLAR ALARM SIREN INSPECTION1. Remove the siren (A) after removing 2 bolts and disconnect the 2P connector from the siren.
2. Test the siren by connecting battery power to the terminal 1 and ground the terminal 2.
The siren should make a sound. If the siren fails to make a sound replace it.