P1699
DTC P1699 TWICE OVERTRIALGENERAL DESCRIPTION
This is a special function for engine start by vehicle manufacturer. The engine can be started for moving from the production line to an area where the key teaching is proceeded.
DTC DESCRIPTION
This DTC is defined as exceeding the maximum limit of twice ignition On.
DTC Detecting Condition:
MONITOR SCANTOOL DATA
1. Ignition "ON" & Engine "OFF".
2. Connect Scan tool and clear the DTCs.
3. Monitor Current Data for Immobilizer System.
4. Retry to communication from the vehicle selection menu although once communication is failed.
5. Is the communication possible between scan tool and Immobilizer system?
YES: Wait for one hour with IG Key On. Be sure that the battery is fully enough to stay for an hour with IG ON.
Disconnecting battery or others manipulation can not reduce this time. After connecting the battery the timer starts again for one hour.
And then, reperform key teaching procedure(Refer to "Reference Data" in General Information")
Go to "Verification of Vehicle Repair" procedure
NO: Fault is intermittent caused by poor contact in the SMARTRA and/or ECM connector or was repaired and ECM memory was not cleared. Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination. deterioration, or damage.
Repair or replace as necessary and then go to "Verification of Vehicle Repair" procedure.
VERIFICATION OF VEHICLE REPAIR
After a repair, it is essential to verify that the fault has been corrected.
1. Connect scan tool and monitor CURRENT DATA to check No. of Learnt key, ECM and KEY status.
2. Select Diagnostic Trouble Codes(DTCs)" mode and Clear the DTCs.
3. Are any DTCs present?
YES: Go to the applicable troubleshooting procedure.
NO: System is performing to specification at this time.