1. ARM Function
1. When using LOCK on the RKE (Remote Keyless Entry) or DOOR KEY the doors will lock, the hazard lamp will blink once within 0.6 secondsand the Anti-Theft System will ARM, if the following conditions have been met.
- The ignition key is removed from the ignition switch.
- All entry points are closed (doors, trunk, and hood)
- Hazard lamp will not blink when driver door key lock switch transits to ARM mode by OFF ON.
2. If either the door or trunk or hood is open when activating LOCK using the RKE, the doors will lock, however the hazard lamp will not flash and the Anti-Theft System will not arm.
3. In Step 2) if the opened entry points are subsequently closed--- the door will lock, the hazard lamp will blink once and the Anti-Theft System will ARM.




4. If the UNLOCK signal is sent by the RKE or DOOR KEY, and either the ignition key is not inserted or entry (door, trunk, hood) to the vehicle is not made within 30 seconds, the LOCK mode will be automatically reset, the hazard lamps will blink, and the Anti-Theft System will rearm. (Key IN = Key Insertion)
(Provided that there is no automatic lock function at a period of 30 seconds, when the UNLOCK is done by the RKE with an entry being open).

2. ALARM Function
1. When a point of entry is opened without RKE or DOOR KEY unlock signal while the Anti-Theft System is in the ARM mode, the hazard lamp and horn alarm will activate (ON/OFF 3 times each) for a period of 27 seconds.
2. Output intervals for the horn alarm and hazard lamps are identical.




3. The alarm sequence, when activated will continue for the duration of the alarm period even when the entry point is closed. (The alarm will reactivate if entry port is reopened after the initial alarm sequence completes.)

3. ALARM CLEARANCE
1. UNLOCK signal is output for 0.5s, alarm and start inhibit signal output become OFF when RKE UNLOCK signal is received or DOOR KEY UNLOCK signal is received.
2. LOCK signal is output for 0.5s, and alarm and start inhibit signal output become OFF when RKE LOCK signal is received or DOOR KEY LOCK signal is received.
3. Alarm and start inhibit signal output become OFF and the state becomes DISARM if KEY IN SW=ON & IGN1 SW=ON & IGN2 SW=ON"is continued for 30s.
In ARM mode, the state becomes DISARM in case of" KEY IN SW=ON & IGN1 SW=ON & IGN2 SW=ON"
4. In ARM mode, the state becomes DISARM at FRONT DOOR KEY UNLOCK ON and the state becomes Alarm Hold state at TRUNK KEY UNLOCK ON.
5. Under ALARM, FRONT DOOR or TRUNK KEY UNLOCK is turned ON, start inhibit signal output becomes OFF, then the state becomes DISARM.
6. If trunk is not opened after TRUNK UNLOCK signal is received with RKE or KEY, the mode enters into ARM mode 30 seconds later after that.




7. If trunk is opened and closed again after TRUNK UNLOCK signal is received with RKE or KEY, the mode enters into ARM mode 30 seconds later after that.

4. Battery Separation
1. When the battery is reconnected after having been disconnected/removed while in ARM mode. ARM mode continues.
2. When the battery is reconnected after having been disconnected/removed, and after the alarm completes, the alarm will restart.
3. When battery is reconnected after having been disconnected/removed during an active alarm, the alarm sequence will restart from the beginning.

5. SECURITY INDICATOR
1. Security indicator: 0.3s ON, 2s OFF under key off.
2. After entering to ARM, security indicator: 0.3s ON, 0.5s OFF in first 8s.
3. After entering to ARM, the first 8s-TIMER is not reset when receiving RKE LOCK or KEY LOCK signal during the cycle: 0.3s ON, 0.5s OFF in the first 8s.
4. 0.3s ON, 2s OFF if ARM is canceled during the cycle 0.3s ON, 0.5s OFF in the first 8s after entering to ARM.
5. After entering to ARM, 0.3s ON, 2s OFF after the first 8s.
6. Security indicator is OFF under key insert to key cylinder.




7. 0.3s ON 0.5s OFF during ALARM mode and PANIC mode.

6. DOOR UNLOCK BY P/WINDOW AND TRUNK OPEN INHIBITION FUNCTIONS
1. Unlock signal output with door unlock switch by P/window and trunk switch is prohibited in case of RKE LOCK under ignition key off.
2. Unlock signal output with door unlock switch by P/window and trunk switch is inhibited in case of door lock with door key under ignition key off.
3. Unlock inhibition function is cancelled in case of RKE UNLOCK while door unlock inhibition function activates.
4. Unlock inhibition function by P/window is cancelled in case of door unlock with door key while door unlock inhibition function activates.
5. Unlock inhibition function by P/window is cancelled at ignition key in & on




6. In ARM mode, unlock signal by P/window input is not output.

7. TRUNK OPEN WITH RKE
1. Trunk release relay is turned ON for 0.5s if trunk signal of RKE is received. (Hold mode under ARM)
2. Trunk release relay is turned ON for 0.5s in case of Trunk release switch OFF->ON.




3. In ARM mode, signal by Trunk release switch input is not output.

8. PANIC alarm
1. PANIC alarm is turned ON for T1 by using horn and hazard if RKE PANIC signal is received.
2. PANIC alarm is turned OFF if (RKE LOCK/UNLOCK/PANIC/TRUNK UNLOCK/KEY IN /DOOR KEY LOCK/DOOR KEY UNLOCK/TRUNK KEY UNLOCK) signals are received during PANIC alarm.
3. PANIC signal output is immediately turned OFF and the state becomes ARM state if the condition for ARM is met during PANIC alarm.
4. The below is about antitheft alarm.
a. Antitheft alarm does not stop even when PANIC signal of RKE is received during the alarm. (PANIC signal reception is ignored)
b. Antitheft alarm signal is output when the condition for antitheft is met during PANIC alarm. (PANIC signal output: OFF)




c. PANIC alarm is turned ON with continuing antitheft function when PANIC signal is received in ARM stand-by / ARM / Alarm end / RELOCK stand-by mode.

9. HORN ANSWER BACK
1. Under DOOR, TRUNK or HOOD: closed, horn and hazard(1s-output) signals are output if RKE LOCK signal is received again within T1 from the moment when the mode transits to ARM mode by RKE LOCK operation and ARM mode is kept.
2. Horn and hazard signals are not output if ARM mode is cancelled for T1.




3. Horn and hazard signal are output even when other LOCK signals of RKE, registered during T1, are received.