Operation CHARM: Car repair manuals for everyone.

Hydraulic Pressure Table

HYDRAULIC PRESSURE TABLE
Under the constant current amount of VFS (200 mA), the line pressure will become as in the table. Be sure that the data can be achieved by specific special facility or device to check the performance of A/T assembly (not on the vehicle), however we can refer the maximum pressure value according to each element.





Measuring condition:
1. PG-A (Input speed): 2,500 rpm
2. Manual valve position: D
3. DCC Solenoid duty: 0 %