Scantool Diagnostics
Monitor Scantool Data
1. Connect 'TPMS exciter' or scantool to Data Link Connector (DLC).
2. Select "TPMS DIAGNOSIS" mode.
3. Select the "FULL" mode of "CURRENT DATA" function.
4. Monitor the parameter of SENSOR 2 on the 'TPMS exciter' or scantool after 20 minutes.
Fig 1) Sensor current data (normal)
Fig 2) Sensor current data (failure)
Fig 3) Connect the DLC for 'TPMS exciter'
5. Is parameter normal ?