Canister Purge Control Valve: Service and Repair
Inspection
1. Turn the ignition switch OFF.
2. Disconnect the PCSV connector.
3. Measure resistance between the PCSV terminals 1 and 2.
4. Check that the resistance is within the specification.
Specification:Refer to Specification Section.
Removal
1. Turn the ignition switch OFF and disconnect the battery negative (-) cable.
2. Disconnect the purge control solenoid valve connector (A) and the vapor hose (B).
3. Remove the purge control solenoid valve (C) after removing the installation bolt.
Installation
CAUTION:
- Install the component with the specified torques.Note that internal damage may occur when the component is dropped. In this case, use it after inspecting.
CAUTION:
- Be careful of foreign material not to flow into the valve.
1. Installation is reverse of removal.
Purge control solenoid valve bracket installation bolt:
9.8 - 11.8 N.m (0.9 - 1.2 kgf.m, 7.2 - 8.7 lb-ft)