Scantool Diagnostics
Automatic Transaxle
P0882 Battery Voltage Low Supply - Scantool Diagnostics
Monitor Scantool Data
1. Connect scan tool to data link connector (DLC)
2. Ignition "ON". & Engine "OFF"
3. Monitor the "Battery Voltage" parameter on the scan tool
Specification : Approx, 9 - 14 V
Fig 1) IG ON
Fig 2) When starting
4. Does "BATTERY VOLTAGE " follow the referance data?