W/Harness Inspection
Power Trunk Module
B2460 Drive Motor and Hall Sensor Error - W/Harness Inspection
Terminal and Connector Inspection
1. Many malfunctions in the electrical system are caused by poor harness(es) and terminals. Faults can also be caused by interference from other electrical systems, and mechanical or chemical damage.
2. Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage.
3. Has a problem been found?
Drive Motor & Hall Sensor Signal Circuit Inspection
1. IG "OFF" and connect GDS.
2. IG "ON" and select "Current Data" menu.
3. Check the service data of "Trunk Lid Latch Switch" with the hand-operated opening and closing of the trunk rid.
Specification : Approx. 12 V
4. Are service data within specifications?