Scantool Diagnostics
Electronic Control Suspension
C1101 Battery Voltage High - Scantool Diagnostics
Monitor GDS Data
1. Connect GDS to Data Link Connector(DLC).
2. Start engine and turn the headight and the heatwire on.
3. Monitor the "BATTERY VOLTAGE" parameter on the GDS
4. Maintaining ENG. RPM at 2,500RPM(idle) over 2 minutes.
Specification :10 - 16V.
5. Is the battery voltage normal?