W/Harness Inspection
Tire Pressure Monitoring
C2510 TREAD LAMP open/short circuit - Inspection/Repair:_:W/Harness Inspection
Terminal and Connector Inspection
1. Many malfunctions in the electrical system are caused by poor harness(es) and terminal condition. Faults can also be caused by interference from other electrical systems, and mechanical or chemical damage.
2. Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage.
3. Has a problem been found?
Power Circuit Inspection
Check for power circuit
1. IG OFF.
2. Disconnect Instrument Cluster connector and TPMS ECU connector.
3. IG ON.
4. Measure voltage between tread lamp power terminal of Cluster harness connector and chassis ground.
Specification :Approx. B+.
5. Is the measured value within specifications?
Control Circuit Inspection
Check for short to battery in harness
1. IG OFF.
2. Disconnect Instrument Cluster connector and TPMS ECU connector.
3. IG ON.
4. Measure voltage between tread lamp control terminal of TPMS ECU harness connector and chassis ground.
Specification :Approx. 0 V
5. Is the measured value within specifications?
Check for short to ground in harness
1. IG OFF.
2. Disconnect Instrument Cluster connector and TPMS ECU connector.
3. Measure resistance between tread lamp control terminal of TPMS ECU harness connector and chassis ground.
Specification :Infinite
4. Is the measured value within specification?
Check for open in harness
1. IG OFF.
2. Disconnect Instument Cluster connector and TPMS ECU connector.
3. Measure resistance between tread lamp control terminal of TPMS ECU harness connector and tread lamp control terminal of Instument Cluster harness connector.
Specification :Approx. 0 Ohms
4. Is the measured value within specification?