Component Inspection
Engine Control
P0625 Generator Field/ F Terminal Circuit Low - Inspection/Repair:_:Component Inspection
Component Inspection
Check Generator
1. Engine starts.
2. Maintain ENG RPM 2,500RPM over 2 minutes.
3. Measure voltage between the battery terminal(+) and the battery terminal(-).
Specification :Approx. 12.5 - 14.7V
4. Is the measured voltage within specification?