System Inspection
Engine Control
P0562 System Voltage Low - Inspection/Repair:_:System Inspection
System Inspection
Check Generator circuit
1. IG "OFF".
2. Disconnect Generator connector.
3. IG "ON".
4. Measure the voltage between lamp terminal of Generator and chassis gound.
5. Measure the voltage between FR terminal of Generator and chassis gound.
Specification :B+
6. Is the measured voltage within specification?