General Information
Air Conditioner
B1258 AQS Sensor Short - General Information
Componet Location
General Description
AQS(Air Quality System) keeps air inside in the most suitable state for driver. In polluted area AQS detects hazardous gas and intercepts inflow automatically, Inversely, In fresh area it allows the inflow of air to prevent the shortage of air and the accumulation of carbon dioxide. AQS sensor is located at front side of condensor and once hazardous gas is detected, it delivers the voltage signal to ECU for closing intake door.
DTC Description
Air conditioner Control Module sets DTC B1258 if Feedback signal of AQS sensor has been detected below 0.1V for 0.3 seconds.
DTC Detecting Condition
Specification
** Voltage value of AQS sensor as a function of position of operating condition.
Preheating Time : (35 ± 2 sec.)
Diagnostic Circuit Diagram