W/Harness Inspection
Tire Pressure Monitoring System
C1665 Initiator supply circuit short to ground - Inspection/Repair:_:W/Harness Inspection
Terminal and Connector Inspection
1. Many malfunctions in the electrical system are caused by poor harness(es) and terminal condition. Faults can also be caused by interference from other electrical systems, and mechanical or chemical damage.
2. Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage.
3. Has a problem been found?
Power Circuit Inspection
1. IG OFF.
2. Disconnect initiator connector and TPMS ECU connector.
3. Measure resistance between initiator's power terminal of TPMS ECU harness connector and chassis ground.
Specification :Infinite
4. Is the measured value within specifications?