General Information
Automatic Transaxle
P0841 Transmission Fluid Pressure Sensor/Switch A Circuit Range/Performance - General Information
Component Location
General Description
The pressure switch seperated from E-MODULE is installed on valve body in transmission. the circuit consists of 1pin. it's OFF when there is no pressure. if the pressure is detected besides 35R, TC,/PCM recognizes error.
DTC Description
This code is set when if the pressure is detected at besides P/35R
DTC Detecting Condition
Specification
- Pressurer switch
- It's operated over 1.4 bar, and not released below 0.5 bar
Diagnostic Circuit Diagram