Component Inspection
Instrument Panel Module
B1613 CAN timeout between IPM and CLU - Inspection/Repair:_:Component Inspection
Component Inspection
Check internal errors of CAN communication units.
1. Connect GDS.
2. IG "ON" and engine "OFF".
3. Select "DTC Analysis" mode.
4. Replace CLU with the new one and check DTC again.
*CAN communication units : IPM(Inter Panel Module), CLU(Cluster), SMK(Smart Key), HU(Head Unit).
5. Is the code erased ?