Panic Alarm Operation
PANIC ALARM OPERATIONRemote keyless entry system may or may not operate vehicle security system (horn and headlamps) as required.
When the remote keyless entry system (panic alarm) is triggered, ground is supplied intermittently
- from smart entrance control unit terminals 21 and 59
- to headlamp (LH and RH) relay terminal 2
- from smart entrance control unit terminal 42
- to horn relay terminal 2.
The headlamp flashes and the horn sounds intermittently.
The alarm automatically turns off after 25 seconds or when smart entrance control unit receives any signal from keyfob.