Operation CHARM: Car repair manuals for everyone.

Operation


REMOTE KEYLESS ENTRY SYSTEM
OPERATION
The remote keyless entry system controls operation of the
- power door lock
- auto door lock
- interior lamp
- panic alarm
- hazard and horn reminder
- power window opener

OPERATED PROCEDURE

Power Door Lock Operation
Smart entrance control unit receives a LOCK signal from keyfob. Smart entrance control unit locks all doors with input of LOCK signal from keyfob.

When an UNLOCK signal is sent from keyfob once, driver's door will be unlocked.

Then, if an UNLOCK signal is sent from keyfob again within 5 seconds, all other door will be unlocked.

Select unlock mode can be changed by CONSULT-II.

Auto Door Lock Operation
Smart entrance control unit will lock all the doors 5 minutes after receiving unlock signal from keyfob. When any of the following operations is performed within 5 minutes, the auto lock operation is cancelled.
- Ignition switch is ON position.
- Open the doors.
- Received lock signal from keyfob.

Auto door lock mode can be changed by CONSULT-II.

Hazard and Horn Reminder
Power is supplied at all times
- to horn relay terminals 1 and 3
- through 7.5 A fuse (No. 52, located in the fusible link and fuse box), and
- to horn relay terminal 6
- through 10 A fuse (No. 54, located in the fusible link and fuse box)

When smart entrance control unit receives LOCK or UNLOCK signal from remote controller with all doors closed, ground is supplied
- to horn relay terminal 2
- through smart entrance control unit terminal 42, and
- to smart entrance control unit terminals 47 and 48 from hazard warning lamp system.

Horn relay are now energized, and hazard warning lamp flashes and horn sounds as a reminder. The hazard and horn reminder has C mode (horn chirp mode) and S mode (non-horn chirp mode).

Operating Function Of Hazard And Horn Reminder:









How to change hazard and horn reminder mode

With CONSULT-II
Hazard and horn reminder can be changed by CONSULT-II.

Without CONSULT-II
When LOCK and UNLOCK signals are sent from the keyfob for more than 2 seconds at the same time, the hazard and horn reminder mode is changed and hazard warning lamp flashes and horn sounds as shown:


NOTE: Reminder mode setting cannot be changed without CONSULT-II for MODES 3, 4, 5, and 6. However, C and S MODES can be changed without CONSULT-II.

Interior Lamp Operation
When the following input signals are both supplied:
- door switch CLOSED (when all the doors are closed);
- driver's door LOCKED; remote keyless entry system turns on interior lamp (for 30 seconds) with input of UNLOCK signal from key-fob.

For detailed description, refer to "INTERIOR, SPOT, VANITY MIRROR AND LUGGAGE ROOM LAMPS".

Panic Alarm Operation
When key switch is OFF (when ignition key is not inserted in key cylinder), remote keyless entry system turns horn and headlamp on and off intermittently with input of PANIC ALARM signal from keyfob.

The alarm automatically turns off after 25 seconds or when smart entrance control unit receives any signal from keyfob.

For detailed description, refer to "VEHICLE SECURITY SYSTEM".

The panic alarm button's pressing time on keyfob can be changed with CONSULT-II.

Power Window Opener Operation
The front power windows open when the unlock button on keyfob is activated and kept pressed for more than 3 seconds with the ignition key OFF. The windows keep opening if the unlock button is continuously pressed. The power window opening stops when the following operations are carried out:

- When the unlock button is kept pressed more than 15 seconds.
- When the ignition switch is turned ON while the power window opening is operated.
- When the unlock button is released.

The unlock button's pressing time can be changed with CONSULT-II.

Door Lock/Unlock and front power window down signal is supplied
- through smart entrance control unit terminal 33
- to front power window main switch terminal 8 and
- to front power window switch RH terminal 11.