Aiming Adjustment



AIMING ADJUSTMENT

CAUTION: Complete all necessary work for laser beam adjustment until the adjustment completes as shown in the procedure. If the procedure does not complete, the ICC system is not.






1. Turn ignition switch OFF.
2. Connect CONSULT-II on the data link connector. Then, start the engine, wait for at least 10 sec., and touch "START".






3. Touch "ICC".






4. Touch "WORK SUPPORT".






5. Touch "LASER BEAM ADJUST".






6. Touch "START".

CAUTION: If the adjustment screen does not appear on CONSULT-II 10 sec. after touching "LASER BEAM ADJUST" screen, the following causes may be considered:
* Target is not set accurately.
* There is not enough space beside the target.
* Deformation of vehicle or the surrounding equipment unit, bracket, or the surrounding equipment is causing inappropriate installation of sensor and aiming may be set out of the adjustable range.
* The area is not suitable for the adjustment work.
* ICC sensor is not clean.
* Laser beam adjustment may not be processed if something interrupts the laser beam.









7. After the CONSULT-II displays "ADJUST THE VERTICAL OF LASER" turn the up-down direction adjustment screw until "U/D CORRECT" value is set in the range of ±4.

CAUTION: Turn the screw slowly. The value change on display is slower than actual movement of the ICC sensor. Wait for 2 seconds every time the screw is turned half a rotation.

NOTE: Turning the screw to the right lifts the aiming and to the left lowers the aiming.






8. When "U/D CORRECT" value indicates ±4, confirm that the margin of value remains within ±4 at least for 2 seconds with no equipment or hand touching the ICC sensor.

When "COMPLETED THE VERTICAL AIMING OF LASER BEAM" appears on screen, touch "END".

CAUTION: Be sure that the margin of "U/D CORRECT" is within ±4 with ICC sensor unit is untouched.






9. Confirm that "ADJUSTING AUTOMATIC HORIZONTAL LASER BEAM AIMING" is on screen and wait for a while (maximum: 10 sec.).






10. Confirm that "NORMALLY COMPLETED" is displayed on CONSULT-II and close the aiming adjustment procedure by touching "END".

CAUTION: Complete all the procedures once "LASER BEAM ADJUST" mode is entered in CONSULT-II. When the procedure is discontinued, the ICC system is inoperable.



Check After The Adjustment
Test the ICC system operation by running test. Refer to "ICC system running test".