Active Test
Caution- Do not perform the active test while driving.
- Active test cannot be started while ICC system warning indicator illuminates.
1. Touch "ACTIVE TEST" on selection screen "CONSULT-II INSPECTION PROCEDURE" .
2. Touch any of "ICC BUZZER 1", "METER LAMP", "STOP LAMP" and "BOOSTER SOL/V 3" on selection screen.
3. Touch necessary item and "START".
4. Active test screen will be shown.
ICC Buzzer 1:
Meter Lamp:
Stop Lamp:
Booster Sol/V3
- Touch any of "MODE 1", "MODE 2", "MODE 3" to check that following operation condition is caused by operating monitor and brake pedal.
- "START" is displayed 10 seconds after operation start. (Active test is completed.)