Operation CHARM: Car repair manuals for everyone.

CONSULT-II Inspection Procedure

CONSULT-II INSPECTION PROCEDURE

CAUTION: If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunctions might be detected in self-diagnosis depending on control unit which carry out CAN communication.

1. Turn ignition switch "OFF".




2. Connect "CONSULT-II" and "CONSULT-II CONVERTER" to the data link connector.
3. Turn ignition switch "ON".




4. Touch "START (NISSAN BASED VHCL)".




5. Touch "BCM".
If "BCM" is not indicated, go to "CONSULT-II Data Link Connector (DLC) Circuit". Diagnostic Aids




6. Touch "MULTI REMOTE ENT".




7. Select diagnosis mode.
"DATA MONITOR", "ACTIVE TEST" and "WORK SUPPORT" are available.