Operation CHARM: Car repair manuals for everyone.

Scan Tool Testing and Procedures




CONSULT-II
CONSULT-II performs the following functions with combination of data receiving, command and transmission using the CAN communication line from the IPDM E/R.

CONSULT-II INSPECTION PROCEDURE

CAUTION: If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunctions might be detected in self-diagnosis depending on control unit which carry out CAN communication.




1. With the ignition switch OFF, connect CONSULT-II and CONSULT-II CONVERTER to the data link connector, then turn the ignition switch ON.




2. Touch "START (NISSAN BASED VHCL)".




3. Touch "IPDM E/R" on "SELECT SYSTEM" screen.
- If "IPDM E/R" is not displayed, print "SELECT SYSTEM" screen, then Refer to "CONSULT-II Data Link Connector (DLC) Circuit". CONSULT-II Checking System




4. Select the desired part to be diagnosed on the "SELECT DIAG MODE" screen.

SELF-DIAG RESULTS

Operation Procedure
1. Touch "SELF-DIAG RESULTS" on "SELECT DIAG MODE" screen.
2. Check display content in self-diagnostic results.

Display Item List:




Display Item List

NOTE:
The details for display of the period are as follows:
- CRNT: Error currently detected with IPDM E/R.
- PAST: Error detected in the past and memorized with IPDM E/R.

DATA MONITOR

Operation Procedure
1. Touch "DATA MONITOR" on "SELECT MONITOR ITEM " screen.




2. Touch "ALL SIGNALS", "MAIN SIGNALS" or "SELECT FROM MENU" on the "DATA MONITOR" screen.
3. Touch "START".
4. Touch the required monitoring item on "SELECT ITEM MENU". In "ALL SIGNALS", all items are monitored. In "MAIN SIGNALS", predetermined items are monitored.
5. Touch "RECORD" while monitoring to record the status of the item being monitored. To stop recording, touch "STOP".

All Items, Main Items, Select Item Menu:




All Items, Main Items, Select Item Menu

CAN DIAGNOSIS SUPPORT MONITOR

Operation Procedure
1. Touch "DATA MONITOR" on "SELECT MONITOR ITEM" screen.
2. Touch "CAN DIAG SUPPORT MNTR" on the "DATA MONITOR" screen.
3. Touch "START".




4. Touch "RECORD" while monitoring to record the status of the item being monitored. To stop recording, touch "STOP".

ACTIVE TEST

Operation Procedure
1. Touch "ACTIVE TEST" on "SELECT DIAG MODE" screen.
2. Touch item to be tested, and check operation.
3. Touch "START".