Unified Meter and A/C Amp
CONSULT-II Function (METER A/C AMP)
CONSULT-II BASIC OPERATION
CAUTION: If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunctions might be detected in self-diagnosis depending on control unit which carry out CAN communication.
1. With the ignition switch OFF, connect "CONSULT-II" and "CONSULT-II CONVERTER" to the data link connector, then turn ignition switch ON.
2. Touch "START (NISSAN BASED VHCL)".
3. Touch "METER A/C AMP" on "SELECT SYSTEM" screen. If "METER A/C AMP" is not indicated, go to GI-40, "CONSULT-II Data Link Connector (DLC) Circuit". Data Link Connector Schematic
4. Select "SELF-DIAG RESULTS", "CAN DIAG SUPPORT MNTR" or "DATA MONITOR".