Operation CHARM: Car repair manuals for everyone.

Vehicle Immobilizer System

CONSULT-II INSPECTION PROCEDURE

CAUTION: If CONSULT-II is used with no connection CONSULT-II CONVERTER, malfunctions might be detected in self-diagnosis depending on control unit which carry out CAN Communication.

1. Turn ignition switch OFF.
2. Insert IVIS (NATS) program card into CONSULT-II.

Program card : NATS (AEN02C)




3. Connect CONSULT-II and "CONSULT-II CONVERTER 7" to data link connector.




4. Turn ignition switch ON.




5. Touch "START".
6. Touch "OTHER".




7. Perform each diagnostic test mode according to each service procedure.

For further information, see the CONSULT-II Operation Manual, NATS-IVIS/NVIS.