Operation CHARM: Car repair manuals for everyone.

Self-Diagnosis / Function Confirmation


Diagnostic Procedure (Steps 1 - 5):




Diagnostic Procedure (Steps 6 - 7):




Diagnostic Procedure (Steps 8 - 11):




Diagnostic Procedure (Steps 12 - 13):




Diagnostic Procedure (Step 14):




FUNCTION CONFIRMATION PROCEDURE




AUXILIARY MECHANISM: TEMPERATURE SETTING TRIMMER
The trimmer compensates for differences in range of ±3 °C (±6 °F) between temperature setting (displayed digitally) and temperature felt by driver.
Operating procedures for this trimmer are as follows:
1. Begin Self-diagnosis STEP-5 mode. Refer to "Self-Diagnosis Function".
2. Press (fan) UP switch to set system in auxiliary mode.
3. Display shows 61 in auxiliary mechanism. It takes approximately 3 seconds.
4. Press temperature switch (driver side) as desired. Temperature will change at a rate of 0.5 °C (1.0 °F) each time a switch is pressed.

CAUTION: A decimal point is not indicated when the display shows "C".

When battery cable is disconnected, trimmer operation is canceled. Temperature set becomes that of initial condition, i.e. 0 °C (0 °F).




AUXILIARY MECHANISM: FOOT POSITION SETTING TRIMMER

Wind distribution ratio in FOOT mode can be set. Operating procedures for this trimmer are as follows:
1. Begin Self-diagnosis STEP-5 mode. Refer to "Self-Diagnosis Function".
2. Press (fan) UP switch to set system in auxiliary mode.
3. Display shows 61 in auxiliary mechanism. It takes approximately 3 seconds.
4. Press the mode switch as desired.

AUXILIARY MECHANISM: INLET PORT MEMORY FUNCTION
When ignition switch is turned from OFF to ON, inlet port can be set to AUTO or manual.

Operating procedures for this trimmer are as follows:
1. Begin self-diagnosis STEP-5 mode. Refer to "Self-Diagnosis Function".
2. Press (fan) UP switch to set system in auxiliary mode.
3. Display shows 61 in auxiliary mechanism. It takes approximately 3 seconds.




4. Press the recirculation (REC) and fresh (FRE) switch as desired.