Inspection Procedure
CONSULT-II Function (ICC)
CONSULT-II OPERATION
CAUTION: If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunctions might be detected in self-diagnosis depending on control unit which carries out CAN communication.
1. Turn ignition switch OFF.
2. Connect CONSULT-II and CONSULT-II CONVERTER to data link connector.
3. Turn ignition switch ON.
4. Touch "START (NISSAN BASED VHCL)".
5. Touch "ICC" on "SELECT SYSTEM" screen.
If "ICC" is not indicated, go to GI-38, "CONSULT-II Data Link Connector (DLC) Circuit". Data Link Connector Schematic
6. Touch "WORK SUPPORT", "SELF-DIAG RESULTS", "DATA MONITOR", "CAN DIAG SUPPORT MNTR", "ACTIVE TEST" or "ECU PART NUMBER" on selection screen.