Additional Service When Replacing Control Unit
ADDITIONAL SERVICE WHEN REPLACING CONTROL UNITADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : Description
When the control unit is replace, the initialization is necessary
If any of the following operations are performed, the initialization is necessary as well as when the control unit is disconnected.
- Power supply to the power window main switch or power window motor is cut off by the removal of battery terminal or the battery fuse is blown.
- Disconnection and connection of power window main switch harness connector.
- Removal and installation of motor from regulator assembly.
- Disconnection and connection of battery negative terminal.
- Removal and installation of glass.
- Removal and installation of door glass run.
The following specified operations can not be performed under the non-initialized condition.
- Auto-up operation
- Anti-pinch function
ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : Special Repair Requirement
INITIALIZATION PROCEDURE
1. Disconnect battery negative terminal or power window main switch connector. Reconnect it after a minute or more.
2. Turn ignition switch ON.
3. Operate power window switch to fully open the window. (This operation is unnecessary if the window is already fully open)
4. Continue pulling the power window switch UP (AUTO-UP operation). Even after glass stops at fully closed position, keep pulling the switch for 2 seconds or more.
5. Initializing procedure is completely.
6. Inspect anti-pinch function.
CHECK ANTI-PINCH FUNCTION
1. Fully open the door window.
2. Place a piece of wood near fully closed position.
3. Close door glass completely with AUTO-UP.
- Check that glass lowers for approximately 150 mm (5.9 in) or 2 seconds without pinching piece of wood and stops.
- Check that glass does not rise when operating the power window main switch while lowering.
CAUTION:
- Perform initial setting when auto-up operation or anti-pinch function does not operate normally.
- Check that AUTO-UP operates before inspection when system initialization is performed.
- Do not check with hands and other body parts because they may be pinched. Do not get pinched.
- It may switch to fail-safe mode if open/close operation is performed continuously without full close.
Perform initial setting in that situation. Refer to PWC-86, "Fail Safe" Power Window Main Switch
- Finish initial setting. Otherwise, next operation cannot be done.
1. Auto-up operation
2. Anti-pinch function