Operation CHARM: Car repair manuals for everyone.

Combination Meters

OPERATION PROCEDURE
1. Turn ignition switch ON, and switch the odo/trip meter to "trip A" or "trip B".

NOTE: If the self-diagnosis function is activated with the "trip A" displayed, only "trip A" display is reset.

2. Turn ignition switch OFF.




3. Turn ignition switch ON while pressing trip transfer switch and trip reset switch at the same time.
4. After ignition switch is turned ON, release trip transfer switch and trip reset switch (within 7 seconds after the ignition switch is turned ON).
5. All the segments on the odo/trip meter, A/T indicator and ICC system display illuminates, and simultaneously the low-fuel warning lamp indicator illuminates. At this time, the unified meter control unit is turned to self-diagnosis mode.






NOTE:
- Check odo/trip meter switch and combination meter power supply and ground circuit when self-diagnosis mode of combination meter does not start. Replace combination meter if the results of the check are normal.
- If any of the segments are not displayed, replace combination meter.




6. Each meter/gauge activates during pressing trip reset switch. (Then low-fuel warning lamp turns OFF.)

NOTE:
- If any of the meters/gauges are not activated, replace the combination meter.
- The figure is reference.